362 TECHNICAL INFORMATION Table 14. Load Correction Factor (Ko) Prime Motor Type Induction Motor Spindle Motor Servo Motor (Peak Output/Rated Output) 200% or Less 201~299% 300% or More Robot Scara Type 2.0 2.0 1.6 1.7 1.8 Injection Mold Machine Mold Fastening · Ball Screw Drive 1.8 1.8 1.3 1.4 1.5 Machine Tool Lathe · Drill Press 1.6 1.3 1.2 1.3 1.4 Machine Tool Milling Machine 1.7 1.3 1.2 1.3 1.4 Conveyor 1.8 1.8 1.4 1.5 1.6 Medical Machinery · Measurement Equipment 1.5 1.5 1.1 0.1 0.2 Packaging Machine 1.6 1.5 1.1 0.1 0.2 Agitator · Mixer Liquid 1.6 1.6 1.2 1.3 1.4 Viscous Material 1.7 1.7 1.3 1.4 1.5 Drilling Machine · Granulator 1.8 1.8 1.4 1.5 1.6 Centrifuge 1.9 1.9 1.5 1.6 1.7 Mills Ball · Rods 2.2 2.2 1.7 1.8 1.9 Printing Machine · Book Making Machine 2.0 2.0 1.6 1.7 1.8 Paper Making Machine Calender · Dryer 2.0 2.0 1.6 1.7 1.8 Textile Machine 2.0 2.0 1.6 1.7 1.8 Wire Related Wire Drawing & Twisting Machine 2.1 2.0 1.6 0.1 0.2 Woodworking Machine 1.7 1.7 1.2 1.3 1.4 Pump 2.0 2.0 1.6 1.7 1.8 Compressor Reciprocating · Rotating 2.0 2.0 1.6 1.7 1.8 Fan · Blower Axial Flow · Roots 2.0 1.8 1.3 1.4 1.5 Generator · Exciter 1.8 1.8 1.4 1.5 1.6 Rubber Industry Machinery · Lumber Mill Machinery 2.0 2.0 1.6 1.7 1.8 Table 15. Idler Correction Factor (Ki) No Idler 0 Inside Idler 0.1×(Qty-1) Outside Idler 0.1×(Qty-1) Table 16. Speed Multiplication Correction Factor (Kr) Operation Duration (Hours/Day) Correction Factor 1 or More Less than 1.25 0 1.25 or More Less than 1.75 0.1 1.75 or More Less than 2.5 0.2 2.5 or More Less than 3.5 0.3 3.5 or More 0.4 Table 17. Operation Time Correction Factor (Kh) Operation Duration (Hours/Day) Correction Factor ≤8 0.1 8<16 0.2 16≤ 0.3 Table 18. Start/Stop Correction Factor (Km) Start/Stop Frequency (Times/Day) Correction Factor ≤10 0.1 11<100 0.2 101<500 0.3 501< 0.4 [Step 2-d] For EV5GT/EV8YU Series t%FTJHO 1PXFS 1E 5SBOTNJTTJPO 1PXFS 1U Y 0WFSMPBE 'BDUPS ,T ∙ Calculate Transmission Power at Motor Rated Power Output. (It is ideal to calculate from the actual load applied to the belt.) ∙ Overload Factor (Ks)=Ko+Ki+Kr+Kh+Km Ko : Load Correction Factor (Table 14) Ki : Idler Correction Factor (Table 15) Kr : Speed Multiplication Correction Factor (Table 16) Kh : Operation Time Correction Factor (Table 17) Km : Start/Stop Correction Factor (Table 18) ∙ When converting the torque (Tq) into transmission power (Pd), calculate the applicable values by using the following expressions. Torque (Tq)=tqxKs Transmitting Power (Pd)=Tqxn/9550 Tq : Design Torque (N·m) tq : Transmission Torque Ks : Overload Factor Pd : Design Power (kW) n : Speed (rpm)

RkJQdWJsaXNoZXIy MTc2MTk0OA==