Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Number of Inputs and Outputs | Analogue Voltage Output (V) | Min. Pressure Cycles | Measuring Range (mbar) | Protection | Min. Bursting Pressure (kPa) | Fill Fluid for Pressure Transfer | Temperature Monitoring | Electrical Design | MAWP (for Applications According to CRN) (bar) | Measuring Range (bar) | Materials | Measuring Range (psi) | Current Consumption (mA) | Design | Measuring Range (kPa) | Application | Conditionally Suitable For | Type of Short-Circuit Protection | Analogue Current Output (mA) | Process Connection | Measuring Element | Operating Voltage (V) | IO-Link Resolution Temperature (K) | Electrical Connection | Ambient Temperature (°C) | Process Connection Sealing | Overvoltage Protection | Min. Bursting Pressure (mbar) | Min. Bursting Pressure (inH2O) | Min. Bursting Pressure (psi) | Output Function | Medium Temperature (°C) | Total Number of Outputs | Max. Load (Ω) | Switching Frequency DC (Hz) | Min. Load Resistance (Ω) | Restrictor Element Integrated | Output Signal | Short-Circuit Protection | Communication Interface | Tightening Torque (Nm) | Special Feature | Application Media | IO-Link Resolution Pressure (mbar) | Surface Characteristics Ra/Rz of the Wetted Parts | Overload Protection | No Dead Space | Min. Insulation Resistance (MΩ) | Short-Circuit Proof | IO-Link Revision | Installation | Display | Materials (Wetted Parts) | Transmission Type | Diaphragm Diameter (mm) | Min. Bursting Pressure (bar) | Measuring Range (inH2O) | MAWP (for Applications According to CRN) (mbar) | Type of Pressure | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
313.09 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-400 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | Yes | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-250 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | Yes | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-100 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-25 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-10 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-2.5 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
313.09 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-1 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
342.58 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-0.25 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
313.09 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | -1-0 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
329.20 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-600 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | Yes | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4404 / 316L); ceramics; FKM | - | - | - | - | - | - | ||
313.09 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-400 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection 1/4"NPT internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | Yes | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-250 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection 1/4"NPT internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-100 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection 1/4"NPT internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-25 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection 1/4"NPT internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-10 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection 1/4"NPT internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-2.5 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection 1/4"NPT internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
313.09 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-1 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection 1/4"NPT internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
342.58 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-0.25 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection 1/4"NPT internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics (99.9 % Al2O3); FKM | - | - | - | - | - | - | ||
316.29 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | -1-1 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread internal thread:M5 | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; Sealing: FKM DIN 3869-14 | - | - | - | - | - | - | ||
307.29 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-250 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; Sealing: FKM | - | - | - | - | - | - | ||
316.29 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-100 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; Sealing: FKM | - | - | - | - | - | - | ||
307.29 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-25 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread internal thread:M5 | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; Sealing: FKM DIN 3869-14 | - | - | - | - | - | - | ||
307.29 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-10 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread internal thread:M5 | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; Sealing: FKM DIN 3869-14 | - | - | - | - | - | - | ||
307.29 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-2.5 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread internal thread:M5 | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; Sealing: FKM DIN 3869-14 | - | - | - | - | - | - | ||
345.68 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-0.25 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread internal thread:M5 | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; Sealing: FKM DIN 3869-14 | - | - | - | - | - | - | ||
345.68 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; (7 days / 1 m water depth / 0.1 bar) | - | - | - | - | - | 0-0.1 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; Sealing: FKM | - | - | - | - | - | - | ||
313.09 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | -1-0 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 20-4 | threaded connection 1/4"NPT internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
313.09 € | 1 | 4 Days | Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-400 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | < 18 | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | - | threaded connection G 1/4 internal thread | - | 16-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | - | - | 2000 | Yes | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-250 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | < 18 | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | - | threaded connection G 1/4 internal thread | - | 16-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | - | - | 2000 | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-100 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | < 18 | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | - | threaded connection G 1/4 internal thread | - | 16-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | - | - | 2000 | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 65 | - | - | - | - | - | 0-25 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | < 18 | - | - | For industrial applications | - | - | - | threaded connection G 1/4 internal thread | - | 16-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | - | - | 2000 | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 65 | - | - | - | - | - | 0-10 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | < 18 | - | - | For industrial applications | - | - | - | threaded connection G 1/4 internal thread | - | 16-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | - | - | 2000 | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 65 | - | - | - | - | - | 0-2.5 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | < 18 | - | - | For industrial applications | - | - | - | threaded connection G 1/4 internal thread | - | 16-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | - | - | 2000 | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
313.09 € | 1 | 4 Days | Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 65 | - | - | - | - | - | 0-1 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | < 18 | - | - | For industrial applications | - | - | - | threaded connection G 1/4 internal thread | - | 16-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | - | - | 2000 | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
342.58 € | 1 | 4 Days | Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 65 | - | - | - | - | - | 0-0.25 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | < 18 | - | - | For industrial applications | - | - | - | threaded connection G 1/4 internal thread | - | 16-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | - | - | 2000 | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
313.09 € | 1 | 4 Days | Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 65 | - | - | - | - | - | -1-0 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | < 18 | - | - | For industrial applications | - | - | - | threaded connection G 1/4 internal thread | - | 16-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | - | - | 2000 | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
329.20 € | 1 | 4 Days | Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-600 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | < 18 | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | - | threaded connection G 1/4 internal thread | - | 16-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | - | - | 2000 | Yes | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4404 / 316L); ceramics; FKM | - | - | - | - | - | - | ||
152.34 € | 1 | 12 Days | Number of analogue outputs: 1 | 0.5-4.5 | 60 million; (at 1.2 times nominal pressure) | - | IP 67; IP 69K | - | - | - | - | - | - | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PPS | 0-3000 | < 12 | - | - | For mobile applications | - | - | - | threaded connection 7/16"- 20 UNF (SAE) external thread | - | 8-32 DC | - | Connector: 1 x DEUTSCH connector (DT04-3P); Maximum cable length: 30 m | -40-100 | FKM | - | - | - | 14500 | - | -40-125 | 1 | - | - | 2000 | Yes | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | Yes | - | - | - | 1.4542 (17-4 PH / 630) | - | - | - | - | - | - | ||
140.01 € | 1 | 3 Days | Number of analogue outputs: 1 | - | 60 million; (at 1.2 times nominal pressure) | - | IP 67; IP 69K | - | - | - | - | - | 0-10 | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread | metallic thin film cell | 8.5-36 DC | - | Connector: 1 x M12 | -25-65 | FKM (to DIN 3869) | - | - | - | - | - | -25-65 | 1 | 755; (Ub = 24 V; (Ub - 8.5 V) / 20.5 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | Yes | - | - | - | 1.4542 (17-4 PH / 630) | - | - | - | - | - | - | ||
140.01 € | 1 | 3 Days | Number of analogue outputs: 1 | - | 60 million; (at 1.2 times nominal pressure) | - | IP 67; IP 69K | - | - | - | - | - | 0-10 | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI | - | - | - | - | For mobile applications | - | - | 4-20 | threaded connection G 1/4 external thread DIN EN ISO 1179-2 | - | 8-32 DC | - | Connector: 1 x M12 | -25-70 | HNBR (to DIN 3869) | - | - | - | - | - | -25-70 | 1 | 755; (Ub = 24 V; (Ub - 8.5 V) / 20.5 mA) | - | - | Yes | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | Yes | - | - | - | 1.4542 (17-4 PH / 630) | - | - | 300 | - | - | - | ||
140.01 € | 1 | 3 Days | Number of analogue outputs: 1 | - | 60 million; (at 1.2 times nominal pressure) | - | IP 67; IP 69K | - | - | - | - | - | 0-6 | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread DIN EN ISO 1179-2 | - | 8.5-36 DC | - | Connector: 1 x M12 | -25-70 | FKM (to DIN 3869) | - | - | - | - | - | -25-70 | 1 | 755; (Ub = 24 V; (Ub - 8.5 V) / 20.5 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | Yes | - | - | - | 1.4542 (17-4 PH / 630) | - | - | 200 | - | - | - | ||
130.54 € | 1 | 5 Days | Number of analogue outputs: 1 | - | 60 million; (at 1.2 times nominal pressure) | - | IP 67; IP 69K | - | - | - | - | - | -1-10 | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread DIN EN ISO 1179-2 | - | 8.5-36 DC | - | Connector: 1 x M12 | -25-70 | FKM (to DIN 3869) | - | - | - | - | - | -25-70 | 1 | 755; (Ub = 24 V; (Ub - 8.5 V) / 20.5 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | Yes | - | - | - | 1.4542 (17-4 PH / 630) | - | - | 300 | - | - | - | ||
156.72 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 60 million; (at 1.2 times nominal pressure) | - | IP 67; IP 69K | - | - | - | - | - | 0-400 | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PA | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread (DIN EN ISO 1179-2) | - | 16-36 DC | - | Connector: 1 x M12 | -40-90 | FKM (to DIN 3869) | - | - | - | - | - | -40-90 | 1 | 720; (Ub = 24 V; (Ub - 8.5 V) / 21.5 mA) | - | - | Yes | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | Yes | - | - | - | 1.4542 (17-4 PH / 630) | - | - | 1700 | - | - | - | ||
156.85 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 60 million; (at 1.2 times nominal pressure) | - | IP 67; IP 69K | - | - | - | - | - | 0-250 | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PA | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread (DIN EN ISO 1179-2) | - | 16-36 DC | - | Connector: 1 x M12 | -40-90 | FKM (to DIN 3869) | - | - | - | - | - | -40-90 | 1 | 720; (Ub = 24 V; (Ub - 8.5 V) / 21.5 mA) | - | - | Yes | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | Yes | - | - | - | 1.4542 (17-4 PH / 630) | - | - | 1200 | - | - | - | ||
156.85 € | 1 | 12 Days | Number of analogue outputs: 1 | - | 60 million; (at 1.2 times nominal pressure) | - | IP 67; IP 69K | - | - | - | - | - | 0-100 | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PA | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 external thread (DIN EN ISO 1179-2) | - | 16-36 DC | - | Connector: 1 x M12 | -40-90 | FKM (to DIN 3869) | - | - | - | - | - | -40-90 | 1 | 720; (Ub = 24 V; (Ub - 8.5 V) / 21.5 mA) | - | - | Yes | Analogue signal | - | - | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | Yes | - | - | - | 1.4542 (17-4 PH / 630) | - | - | 1000 | - | - | - | ||
177.33 € | 1 | 12 Days | Number of analogue outputs: 1 | 0-5 | 50 million | - | IP 67; IP 69K | - | - | - | - | - | - | stainless steel (1.4404 / 316L); PA PACM 12 (TROGAMID) | 0-5000 | < 6 | - | - | For mobile applications | - | - | - | threaded connection 7/16"- 20 UNF (SAE) external thread | - | 8-36 DC | - | Connector: 1 x M12 | -40-90 | - | - | - | - | 23200 | - | -40-90 | 1 | - | - | 2000 | Yes | Analogue signal | - | - | - | - | Liquids and gases | - | - | - | - | 100; (80 V DC) | - | - | - | - | stainless steel (1.4404 / 316L); FPM Viton | - | - | - | - | - | relative pressure | ||
172.00 € | 1 | 12 Days | Number of analogue outputs: 1 | 0-10 | 50 million | - | IP 67; IP 69K | - | - | - | - | - | - | stainless steel (1.4404 / 316L); PA | 0-750 | < 6 | - | - | For industrial applications | - | - | - | threaded connection 7/16"- 20 UNF internal thread | - | 16-36 DC | - | Connector: 1 x M12 | -25-90 | - | - | - | - | 8702 | - | -25-90 | 1 | - | - | 2000 | - | Analogue signal | - | - | - | - | Liquids and gases | - | - | - | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4404 / 316L) | - | - | - | - | - | relative pressure | ||
180.06 € | 1 | 12 Days | Number of analogue outputs: 1 | 0.5-4.5 | 50 million | - | IP 67; IP 69K | - | - | - | - | - | 0-400 | stainless steel (1.4404 / 316L); PA | - | < 6 | - | - | For mobile applications | - | - | - | threaded connection G 1/4 external thread | - | 5 DC; (ratiometric) | - | Connector: 1 x M12 | -25-90 | - | - | - | - | - | - | -25-90; (on request: -40-100 °C) | 1 | - | - | 5000 | Yes | Analogue signal | - | - | - | - | Liquids and gases | - | - | - | - | 100; (80 V DC) | - | - | - | - | stainless steel (1.4404 / 316L); FKM | - | - | 1600 | - | - | relative pressure | ||
507.37 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | 0-250 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 internal thread | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 3 x LED, green (bar, psi, MPa) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
507.37 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | 0-100 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 internal thread | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 3 x LED, green (bar, psi, MPa) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (99.9%; ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
507.37 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | --1-25 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 internal thread | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 3 x LED, green (bar, psi, MPa) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (99.9%; ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
507.37 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | -1-10 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 internal thread | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 3 x LED, green (bar, psi, MPa) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (99.9%; ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
507.37 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | -0.125-2.5 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 internal thread | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 3 x LED, green (bar, psi, kPa) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (99.9%; ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
522.89 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | -1-1 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 internal thread | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 5 x LED, green (mbar, psi, kPa, inH2O, inHg) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
512.71 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | 0-250 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; EPDM | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 external thread internal thread:M5; DIN EN ISO 1179-2 | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | EPDM | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 3 x LED, green (bar, psi, MPa) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
512.71 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | 0-100 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; EPDM | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 external thread internal thread:M5; DIN EN ISO 1179-2 | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | EPDM | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 3 x LED, green (bar, psi, MPa) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (99.9%; ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
512.71 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | --1-25 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; EPDM | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 external thread internal thread:M5; DIN EN ISO 1179-2 | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | EPDM | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 3 x LED, green (bar, psi, MPa) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (99.9%; ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
512.71 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | -1-10 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; EPDM | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 external thread internal thread:M5; DIN EN ISO 1179-2 | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | EPDM | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 3 x LED, green (bar, psi, MPa) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (99.9%; ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
512.71 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | -0.125-2.5 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; EPDM | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 external thread internal thread:M5; DIN EN ISO 1179-2 | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | EPDM | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 3 x LED, green (bar, psi, kPa) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (99.9%; ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
527.86 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable 1:5) | 100 million | - | IP 65; IP 67 | - | - | - | PNP/NPN | - | -1-1 | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC; EPDM | - | < 35 | - | - | For industrial applications | - | pulsed | 4-20; (scalable 1:5) | threaded connection G 1/4 external thread internal thread:M5; DIN EN ISO 1179-2 | ceramic-capacitive pressure measuring cell | 18-30 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | EPDM | - | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 500 | < 500 | 2000 | No (can be retrofitted) | Switching signal; analogue signal; IO-Link; (configurable) | Yes | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | Display unit: 5 x LED, green (mbar, psi, kPa, inH2O, inHg) switching status: 2 x LED, yellow measured values: alphanumeric display, red/green 4-digit | stainless steel (1.4404 / 316L); Al2O3 (99.9%; ceramics); EPDM | COM2 (38.4 kBaud) | - | - | - | - | - |
Loading...
Protection Class | III | Reverse Polarity Protection | Yes |
---|
Configure
Basic Attributes
Number of Inputs and Outputs
Analogue Voltage Output(V)
Min. Pressure Cycles
Measuring Range(mbar)
Protection
Min. Bursting Pressure(kPa)
Fill Fluid for Pressure Transfer
Temperature Monitoring
Electrical Design
MAWP (for Applications According to CRN)(bar)
Measuring Range(bar)
Materials
Measuring Range(psi)
Current Consumption(mA)
Design
Measuring Range(kPa)
Application
Conditionally Suitable For
Type of Short-Circuit Protection
Analogue Current Output(mA)
Process Connection
Measuring Element
Operating Voltage(V)
IO-Link Resolution Temperature(K)
Electrical Connection
Ambient Temperature(°C)
Process Connection Sealing
Overvoltage Protection
Min. Bursting Pressure(mbar)
Min. Bursting Pressure(inH2O)
Min. Bursting Pressure(psi)
Output Function
Medium Temperature(°C)
Total Number of Outputs
Max. Load(Ω)
Switching Frequency DC(Hz)
Min. Load Resistance(Ω)
Restrictor Element Integrated
Output Signal
Short-Circuit Protection
Communication Interface
Tightening Torque(Nm)
Special Feature
Application Media
IO-Link Resolution Pressure(mbar)
Surface Characteristics Ra/Rz of the Wetted Parts
Overload Protection
No Dead Space
Min. Insulation Resistance(MΩ)
Short-Circuit Proof
IO-Link Revision
Installation
Display
Materials (Wetted Parts)
Transmission Type
Diaphragm Diameter(mm)
Min. Bursting Pressure(bar)
Measuring Range(inH2O)
MAWP (for Applications According to CRN)(mbar)
Type of Pressure
Filter by standard shipping days
Optional Attributes