Technical Data:

Number of Inputs and Outputs: Number of analogue outputs: 1

Analogue Voltage Output: 0-10 V

Min. Pressure Cycles: 100 million

Measuring Range: - mbar

Protection: IP 65


Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

PA9029

Part Number
PA9029
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Number of Inputs and Outputs Analogue Voltage Output
(V)
Min. Pressure Cycles Measuring Range
(mbar)
Protection Min. Bursting Pressure
(kPa)
Fill Fluid for Pressure Transfer Temperature Monitoring Electrical Design MAWP (for Applications According to CRN)
(bar)
Measuring Range
(bar)
Materials Measuring Range
(psi)
Current Consumption
(mA)
Design Measuring Range
(kPa)
Application Conditionally Suitable For Type of Short-Circuit Protection Analogue Current Output
(mA)
Process Connection Measuring Element Operating Voltage
(V)
IO-Link Resolution Temperature
(K)
Electrical Connection Ambient Temperature
(°C)
Process Connection Sealing Overvoltage Protection Min. Bursting Pressure
(mbar)
Min. Bursting Pressure
(inH2O)
Min. Bursting Pressure
(psi)
Output Function Medium Temperature
(°C)
Total Number of Outputs Max. Load
(Ω)
Switching Frequency DC
(Hz)
Min. Load Resistance
(Ω)
Restrictor Element Integrated Output Signal Short-Circuit Protection Communication Interface Tightening Torque
(Nm)
Special Feature Application Media IO-Link Resolution Pressure
(mbar)
Surface Characteristics Ra/Rz of the Wetted Parts Overload Protection No Dead Space Min. Insulation Resistance
(MΩ)
Short-Circuit Proof IO-Link Revision Installation Display Materials (Wetted Parts) Transmission Type Diaphragm Diameter
(mm)
Min. Bursting Pressure
(bar)
Measuring Range
(inH2O)
MAWP (for Applications According to CRN)
(mbar)
Type of Pressure

313.09 €

1 4 Days Number of analogue outputs: 10-10100 million-IP 65------1-0stainless steel (1.4404 / 316L); FKM; PA; EPDM/X-< 18--For industrial applications---threaded connection G 1/4 internal thread-16-32 DC-Connector: 1 x M12; Contacts: gold-plated-25-80-------25-90; (on request: -40-90 °C)1--2000No (can be retrofitted)Analogue signal---Gold-plated contactsLiquids and gases--Yes-100; (500 V DC)----stainless steel (1.4305 / 303); ceramics; FKM------

Loading...

  1. 1

Basic information

Protection Class III Reverse Polarity Protection Yes

This page is Electronic Pressure Sensor, part number PA9029.
You can find the detail information about specifications and dimensions on part number PA9029.

Variation of this product

Part Number
PA3023
PA3024
PA3026
PA9060
PC1732
PC5024
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Number of Inputs and Outputs Analogue Voltage Output
(V)
Min. Pressure Cycles Measuring Range
(mbar)
Protection Min. Bursting Pressure
(kPa)
Fill Fluid for Pressure Transfer Temperature Monitoring Electrical Design MAWP (for Applications According to CRN)
(bar)
Measuring Range
(bar)
Materials Measuring Range
(psi)
Current Consumption
(mA)
Design Measuring Range
(kPa)
Application Conditionally Suitable For Type of Short-Circuit Protection Analogue Current Output
(mA)
Process Connection Measuring Element Operating Voltage
(V)
IO-Link Resolution Temperature
(K)
Electrical Connection Ambient Temperature
(°C)
Process Connection Sealing Overvoltage Protection Min. Bursting Pressure
(mbar)
Min. Bursting Pressure
(inH2O)
Min. Bursting Pressure
(psi)
Output Function Medium Temperature
(°C)
Total Number of Outputs Max. Load
(Ω)
Switching Frequency DC
(Hz)
Min. Load Resistance
(Ω)
Restrictor Element Integrated Output Signal Short-Circuit Protection Communication Interface Tightening Torque
(Nm)
Special Feature Application Media IO-Link Resolution Pressure
(mbar)
Surface Characteristics Ra/Rz of the Wetted Parts Overload Protection No Dead Space Min. Insulation Resistance
(MΩ)
Short-Circuit Proof IO-Link Revision Installation Display Materials (Wetted Parts) Transmission Type Diaphragm Diameter
(mm)
Min. Bursting Pressure
(bar)
Measuring Range
(inH2O)
MAWP (for Applications According to CRN)
(mbar)
Type of Pressure

304.32 €

1 4 Days Number of analogue outputs: 1-100 million-IP 65-----0-25stainless steel (1.4404 / 316L); FKM; PA; EPDM/X----For industrial applications--4-20threaded connection G 1/4 internal thread-9.6-32 DC-Connector: 1 x M12; Contacts: gold-plated-25-80-------25-90; (on request: -40-90 °C)1720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA)--No (can be retrofitted)Analogue signal---Gold-plated contactsLiquids and gases--Yes-100; (500 V DC)----stainless steel (1.4305 / 303); ceramics; FKM------

304.32 €

1 4 Days Number of analogue outputs: 1-100 million-IP 65-----0-10stainless steel (1.4404 / 316L); FKM; PA; EPDM/X----For industrial applications--4-20threaded connection G 1/4 internal thread-9.6-32 DC-Connector: 1 x M12; Contacts: gold-plated-25-80-------25-90; (on request: -40-90 °C)1720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA)--No (can be retrofitted)Analogue signal---Gold-plated contactsLiquids and gases--Yes-100; (500 V DC)----stainless steel (1.4305 / 303); ceramics; FKM------

304.32 €

1 4 Days Number of analogue outputs: 1-100 million-IP 65-----0-2.5stainless steel (1.4404 / 316L); FKM; PA; EPDM/X----For industrial applications--4-20threaded connection G 1/4 internal thread-9.6-32 DC-Connector: 1 x M12; Contacts: gold-plated-25-80-------25-90; (on request: -40-90 °C)1720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA)--No (can be retrofitted)Analogue signal---Gold-plated contactsLiquids and gases--Yes-100; (500 V DC)----stainless steel (1.4305 / 303); ceramics; FKM------

329.20 €

1 4 Days Number of analogue outputs: 10-10100 million-IP 68; IP 69K-----0-600stainless steel (1.4404 / 316L); FKM; PA; EPDM/X-< 18--For industrial applicationsuse in gases at pressures > 25 bar only on request--threaded connection G 1/4 internal thread-16-32 DC-Connector: 1 x M12; Contacts: gold-plated-25-80-------25-90; (on request: -40-90 °C)1--2000YesAnalogue signal---Gold-plated contactsLiquids and gases--Yes-100; (500 V DC)----stainless steel (1.4404 / 316L); ceramics; FKM------

152.34 €

1 12 Days Number of analogue outputs: 10.5-4.560 million; (at 1.2 times nominal pressure)-IP 67; IP 69K------1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PPS0-3000< 12--For mobile applications---threaded connection 7/16"- 20 UNF (SAE) external thread-8-32 DC-Connector: 1 x DEUTSCH connector (DT04-3P); Maximum cable length: 30 m-40-100FKM---14500--40-1251--2000YesAnalogue signal--25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating)-Liquids and gases--Yes-100; (500 V DC)Yes---1.4542 (17-4 PH / 630)------

140.01 €

1 3 Days Number of analogue outputs: 1-60 million; (at 1.2 times nominal pressure)-IP 67; IP 69K-----0-101.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI----For industrial applications--4-20threaded connection G 1/4 external threadmetallic thin film cell8.5-36 DC-Connector: 1 x M12-25-65FKM (to DIN 3869)------25-651755; (Ub = 24 V; (Ub - 8.5 V) / 20.5 mA)--No (can be retrofitted)Analogue signal--25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating)-Liquids and gases--Yes-100; (500 V DC)Yes---1.4542 (17-4 PH / 630)------

Tech Support