Heat Resistant Duct Hoses / For Hot Air Generating Units

Heat Resistant Duct Hoses / For Hot Air Generating Units

Click on this image to zoom in.

Click on this image to zoom in.

  • Heat Resistant Duct Hoses / For Hot Air Generating Units
  • Heat Resistant Duct Hoses / For Hot Air Generating Units
  • Heat Resistant Duct Hoses / For Hot Air Generating Units
  • Heat Resistant Duct Hoses / For Hot Air Generating Units
  • Heat Resistant Duct Hoses / For Hot Air Generating Units
  • Heat Resistant Duct Hoses / For Hot Air Generating Units
[Features] A heat resistant duct hose. -Cutting service is available.

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Heat Resistant Duct Hoses/For Hot Air Generating Units:Related Image

TypeApplication MaterialOperating Temp. Range (°C)
Main BodyOthers
HOCTDLow Dust Generation TypeAluminum Polyester ClothReinforcement Spiral: Zinc Plating-20~130°C
HOTDHeat-Resistant TypeSpecial Coating Glass ClothReinforcement Spiral: EN 1.4301 Equiv.-20~250°C
HOTDSHeat-Resistant TypeAluminum Glass ClothReinforcement Spiral: EN 1.0330 Equiv. (Zinc Plating)-20~180°C
HOTDHHeat-Resistant TypeEN 1.4301 Equiv.Reinforcement Spiral: EN 1.4301 Equiv.30~450°C
HOTDKHeat-Resistant TypeEN 1.4301 Equiv.Reinforcement Spiral: EN 1.4301 Equiv.~600°C
HOTDAHeat Resistant · Heat Retention TypeAluminumReinforcement Spiral: Glass Fiber-30~200°C

Specifications

Part Number-Hose Length
HOTDK50-3.2
Part NumberHose Length
0.1m Increment
Hose I.D. (Reference) (mm)DPAllowable Pressure
Range (MPa)
Allowable Decompression
(Ambient Temp.) (kPa)
Reference Mass (g/m)Allowable Bending Radius (mm)Unit Price Hose Unit Price/m
TypeNo.1 ~ 5 pc(s).
HOCTD
(Low Dust Generation Type)
500.5~55154.5200~0.007-8.5370120
75768020-7530160
100102.510623-6.5640210
125127.513123-6.5770250
15015215523-6945300
HOTD
(Heat Resistant Temperature 250°C Type)
500.5~55154.5200~0.007-8.5360110
656771.520-8480140
75768020-7525160
909194.523-6.5545190
100102.510623-6.5635210
HOTDS
(Heat Resistant Temperature 180°C Type)
500.5~55154.5200~0.007-8.5405110
HOTDH
(Heat Resistant Temperature 450°C Type)
500.5~252.556200~0.007-10.5365170
656771.520-10460210
75768020-10525240
9091.59523-9570290
100102.510623-8635320
HOTDK
(Heat Resistant Temperature 600°C Type)
500.5~451.256.8-0~0.027-2722075
6566.271.8--2728098
7576.281.8--27320113
8081.286.8--27340120
100101.7107.3--27420200
"HOTDA
(Heat Insulating Layer Coated Type)"
500.5~250.91074.10.009-9470200
7575.91324.10.007-7.2590300
100101.41574.10.006-6720400
For orders larger than indicated quantity, please check with WOS.
Hose length refers to the length when the hose is stretched without tensile load.
(The allowable pressure is the maximum design pressure.
The allowable reduction pressure is the maximum negative pressure that can be applied to the hose under ambient temperature.
Above range is for Hose Body only. Use data as reference.
Use two hose clamps for each installation location to secure the hose.

Part Number:  

    3D preview is not available, because the part number has not yet been determined.

  • In order to open the 3D preview, the part number must be fixed.
Loading...
Part Number
HOTD50-[0.5-5/0.1]
HOTD65-[0.5-5/0.1]
HOTD75-[0.5-5/0.1]
HOTD90-[0.5-5/0.1]
HOTD100-[0.5-5/0.1]
HOTDA50-[0.5-2/0.1]
HOTDA75-[0.5-2/0.1]
HOTDA100-[0.5-2/0.1]
HOTDH50-[0.5-2/0.1]
HOTDH65-[0.5-2/0.1]
HOTDH75-[0.5-2/0.1]
HOTDH90-[0.5-2/0.1]
HOTDH100-[0.5-2/0.1]
HOTDK65-[0.5-4/0.1]
HOTDK75-[0.5-4/0.1]
HOTDK100-[0.5-4/0.1]
HOTDS50-[0.5-5/0.1]
Part NumberMinimum order quantityVolume Discount
Standard
Shipping Days
?
Material Properties I.D. d
(mm)
O.D. D
(mm)
Applicable Fluid Max. Allowable Pressure (below Ambient Temperature)
(MPa)
Operating Temperature Range
(℃)
Allowable Bending Radius
(mm)
Nominal Nominal Dia. Operating Temperature Range (°C) Hose Length
(m)
1 9 Days Specially Coated Glass ClothFlame Resistance / Heat-Resistant Alignment Type5154.5Air / Sparks0.00730~25011050--20~2500.5 ~ 5
1 7 Days Specially Coated Glass ClothFlame Resistance / Heat-Resistant Alignment Type6771.5Air / Sparks0.00730~25014065--20~2500.5 ~ 5
1 9 Days Specially Coated Glass ClothFlame Resistance / Heat-Resistant Alignment Type7680Air / Sparks0.00730~25016075--20~2500.5 ~ 5
1 7 Days Specially Coated Glass ClothFlame Resistance / Heat-Resistant Alignment Type9194.5Air / Sparks0.00730~25019090--20~2500.5 ~ 5
1 9 Days Specially Coated Glass ClothFlame Resistance / Heat-Resistant Alignment Type102.5106Air / Sparks0.00730~250210100--20~2500.5 ~ 5
1 7 Days [Aluminum] AluminumHeat-Resistant Alignment Type50.9107Air0.009-30~20030050--30~2000.5 ~ 2
1 7 Days [Aluminum] AluminumHeat-Resistant Alignment Type75.9132Air0.0072-30~20040075--30~2000.5 ~ 2
1 7 Days [Aluminum] AluminumHeat-Resistant Alignment Type101.4157Air0.006-30~200200100--30~2000.5 ~ 2
1 9 Days EN 1.4301 Equiv.Heat-Resistant Alignment Type52.556.6Gases containing Acid and Alkali / Air0.00730~45017050-30~4500.5 ~ 2
1 9 Days EN 1.4301 Equiv.Heat-Resistant Alignment Type6771.5Gases containing Acid and Alkali / Air0.00730~45021065-30~4500.5 ~ 2
1 9 Days EN 1.4301 Equiv.Heat-Resistant Alignment Type7680Gases containing Acid and Alkali / Air0.00730~45024075-30~4500.5 ~ 2
1 9 Days EN 1.4301 Equiv.Heat-Resistant Alignment Type91.595Gases containing Acid and Alkali / Air0.00730~45029090-30~4500.5 ~ 2
1 9 Days EN 1.4301 Equiv.Heat-Resistant Alignment Type102.5106Gases containing Acid and Alkali / Air0.00730~450320100-30~4500.5 ~ 2
1 7 Days EN 1.4301 Equiv.Heat-Resistant Alignment Type66.271.8Air0.027~60098-650~6000.5 ~ 4
1 7 Days EN 1.4301 Equiv.Heat-Resistant Alignment Type76.281.8Air0.027~600113-750~6000.5 ~ 4
1 7 Days EN 1.4301 Equiv.Heat-Resistant Alignment Type101.7107.3Air0.027~600200-1000~6000.5 ~ 4
1 7 Days [Aluminum] AluminumFlame Resistance / Heat-Resistant Alignment Type5154.5Air0.007-30~20011050--20~1800.5 ~ 5

Loading...

  1. 1

More Information

 ■  Application of HOTDS (for Fixed Plumbing)
Elastic, and can be fixed at any angle or in any direction.
(Do not stretch/release the hose repeatedly.)
Aluminum Glass Cloth Sheets are highly flame-resistant.
(Flame Retardant Class 1-certificated)
Hoses have no tightness.
 ■  Application of HOTD (for Non-Fixed Plumbing)
Flexible and easy to store and transport.
Special Coating Glass Clothes used for the products are highly elastic and flame resistant.
(Flame Retardant Class 1-certificated)
Hoses have no tightness.
 ■  Application of HOTDH (for Fixed Plumbing)
Though designed for fixed plumbing, it can form curved portions.
(Do not stretch/release the hose repeatedly.)
Hoses have no tightness.
 ■  Application of HOTDA (for Fixed Plumbing)
Requires no heat retention after installation, and thus, shortens work period.

Basic information

Cutting Service Usage Yes With or w/o Cuffs Not Provided

Complementary Products

Tech Support

Technical Support
Tel:+49 69 668173-0 / FAX:+49 69 668173-360