[Standard] X-Axis / Cross Roller (Part Numbers - CAD Download)

[Standard] X-Axis / Cross Roller
  • Promotional pricing
  • Volume Discount
  • Order quantities extended (D-JIT)
  • Stock

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

[Standard] X-Axis/Cross Roller:Related Image

Material: Aluminum Alloy
Surface Treatment: Black Anodize

Specifications

Model (Type, A)
XCRS60
Part NumberTop ViewFront ViewSide View
TYPEA(B)Travel Distance (mm)EF(J)DGTPQXd1d2
XCRS2529± 3.2711.8(6.8)9.59.315610.5202.44.22.5
 4026± 6.5819(10.8)1313201014.5323.463.3
5023819(10.8)1313201014.5403.463.5
 6021819(10.8)1313201014.5504.584.4
 8022819(10.8)1313201014.5704.584.4
9034.8±12.5819(10.8)1313201014.5804.585.3
10020.8819(10.8)1313201014.5904.585.3
12088±2513.526(10.8)19.111201014.51004.585.3

• Performance
AStage Surface
(mm)
Load Capacity (N)Max. Holding Force (N)
(Ref.)
Travel AccuracyAllowable Moment (N•m)Moment Rigidity ("/N•cm)ParallelismWeight
(kg)
Unit Price
HorizontalVerticalStraightnessMotion ParallelismPitchingYawingRollingPitchingYawingRolling
 25 25x 259.84.96030µm30µm1.10.80.43.032.851.8050µm0.04 
 40 40x 4019.69.82.72.22.00.380.420.280.14 
 50 50x 5029.414.73.53.03.30.200.220.120.18 
 60 60x 604919.65.24.35.50.120.110.070.24 
 80 80x 8098497019.215.117.30.050.050.0460µm0.39 
 90 90x 90117.625.020.022.00.050.050.040.49 
100100×10014736.030.033.00.060.070.050.58 
120120×12019657.244.766.70.030.020.010.95 
Max. Holding Force (Ref.) will vary depending on the tightening torque variations. Ensure adequate safety margins for design.
Micrometer Head Resolution: 10µm/division

Alterations

[Standard] X-Axis/Cross Roller:Related Image

Part Number:  

    3D preview is not available, because the part number has not yet been determined.

  • In order to open the 3D preview, the part number must be fixed.
Loading...
Part Number
XCRS90
XCRS90-A
XCRS90-AR
XCRS90-AZ
XCRS90-AZR
XCRS90-CR
XCRS100-A
XCRS100-AR
XCRS100-AZ
XCRS100-AZR
XCRS100-CR
XCRS120
XCRS120-A
XCRS120-AR
XCRS120-AZ
XCRS120-AZR
XCRS120-CR
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
RoHSTable Size (Length) L (Range Selectable)
(mm)
Table Size (Width) W (Range Selectable)
(mm)
Load Capacity (Range Selectable)
(N)
Travel Distance (Range Selectable) Table Size (Thickness) H (Range Selectable)
(mm)
Table Size (Length) L
(mm)
Table Size (Width) W
(mm)
Allowable Load
(N)
Travel Distance (X-Axis)
(mm)
Table Size (Thickness) H
(mm)
Moment Rigidity (Pitching)
("/N•cm)
Moment Rigidity (Yawing)
("/N•cm)
Moment Rigidity (Rolling)
("/N•cm)
Micrometer Head Position

188.91 €

1 Available 5 Days 1061~9061~90100.1 or More±10~30mm15.1-209090117.6±12.5200.050.050.04Standard

188.91 €

1 Available 5 Days 1061~9061~90100.1 or More±10~30mm15.1-209090117.6±12.5200.050.050.04Center (A)

188.91 €

1 Available 5 Days 1061~9061~90100.1 or More±10~30mm15.1-209090117.6±12.5200.050.050.04Center Mount - Left/Right Reversed (AR)

188.91 €

1 Available 5 Days 1061~9061~90100.1 or More±10~30mm15.1-209090117.6±12.5200.050.050.04Center Mount - Top/Bottom Reversed (AZ)

188.91 €

1 Available 5 Days 1061~9061~90100.1 or More±10~30mm15.1-209090117.6±12.5200.050.050.04Center Mount - Left/Right and Top/Bottom Reversed (AZR)

188.91 €

1 Available 5 Days 1061~9061~90100.1 or More±10~30mm15.1-209090117.6±12.5200.050.050.04Side Mount - Left/Right Reversed (CR)

226.68 €

1 Available 5 Days 1091~12091~120100.1 or More±10~30mm15.1-20100100147±12.5200.060.070.05Center (A)

226.68 €

1 Available 5 Days 1091~12091~120100.1 or More±10~30mm15.1-20100100147±12.5200.060.070.05Center Mount - Left/Right Reversed (AR)

226.68 €

1 Available 5 Days 1091~12091~120100.1 or More±10~30mm15.1-20100100147±12.5200.060.070.05Center Mount - Top/Bottom Reversed (AZ)

226.68 €

1 Available 5 Days 1091~12091~120100.1 or More±10~30mm15.1-20100100147±12.5200.060.070.05Center Mount - Left/Right and Top/Bottom Reversed (AZR)

226.68 €

1 Available 5 Days 1091~12091~120100.1 or More±10~30mm15.1-20100100147±12.5200.060.070.05Side Mount - Left/Right Reversed (CR)

314.85 €

1 Available 5 Days 1091~12091~120100.1 or More±10~30mm15.1-20120120196±25200.030.020.01Standard

314.85 €

1 Available 5 Days 1091~12091~120100.1 or More±10~30mm15.1-20120120196±25200.030.020.01Center (A)

314.85 €

1 Available 5 Days 1091~12091~120100.1 or More±10~30mm15.1-20120120196±25200.030.020.01Center Mount - Left/Right Reversed (AR)

314.85 €

147.98 €

1 Available Same day

Stock

1091~12091~120100.1 or More±10~30mm15.1-20120120196±25200.030.020.01Center Mount - Top/Bottom Reversed (AZ)

314.85 €

1 Available 5 Days 1091~12091~120100.1 or More±10~30mm15.1-20120120196±25200.030.020.01Center Mount - Left/Right and Top/Bottom Reversed (AZR)

314.85 €

1 Available 5 Days 1091~12091~120100.1 or More±10~30mm15.1-20120120196±25200.030.020.01Side Mount - Left/Right Reversed (CR)

Loading...

  1. 1

More Information

Notes on Vertical Use of X-Axis Stages
•The carriage may drop if mounted vertically with the micrometer head pointed down with Standard, CR, A or AR selected. (A load exceeding the spring pull force will cause the carriage to drop.)
•The carriage does not drop when mounted vertically with the micrometer head pointed down with AZ or AZR selected. However, do not apply a load exceeding the specified vertical load capacity for X-Axis as it may decrease the accuracy.

Basic information

Feeding Method EN 1.4125 Equiv. Table Material Aluminum Alloy Table Surface Treatment Black Anodized Aluminum
Guiding Mechanism Cross Roller Category Main Body Type X-Axis
Table Straightness(µm) 30 Table Parallelism(µm) 30 Feed Knob Position Side
Clamp Standard Reversed Standard Through Hole (Table Center Hole) No
Feeding Method (Micrometer Type) Standard Feeding Method (Travel per Rotation)(mm) 0.5

Complementary Products

Tech Support

Technical Support
Tel:+49 69 668173-0 / FAX:+49 69 668173-360