Manufacturer part number: SR5906
Brand: IFM ELECTRONIC
Price: 323.76 €
Delivery time: 4 Days
Response Time: - s
Protection: IP 67; (with sensor attached)
Power-On Delay Time: 10 s
Electrical Design: relay
Materials: stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
SR5906
Part Number
|
---|
SR5906 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Response Time (s) | Protection | Power-On Delay Time (s) | Electrical Design | Materials | Current Consumption (mA) | Protection Class | Application | Type of Short-Circuit Protection | Storage Temperature (°C) | Connection | Switching Function Flow Monitoring | Operating Voltage (V) | Frequency AC (Hz) | Ambient Temperature (°C) | Reverse Polarity Protection | Repeatability of the Set Switch Point (K) | Temperature Range (°C) | Switching Function Wire Break Monitoring | Adjustment of the Switch Point | Short-Circuit Protection | Operating Voltage Tolerance (%) | Performance in Case of a Fault | Housing | Max. Voltage Drop Switching Output DC (V) | Switching Cycles (Mechanical) | Switch Point Setting | Selection Liquids / Gases | Application Media | Switching Function Temperature Monitoring | Permanent Current Rating of Switching Output DC (mA) | Overload Protection | Contact Rating | Max. Power Consumption (VA) | Short-Circuit Proof | Dimensions (mm) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
323.76 € | 1 | 4 Days | - | IP 67; (with sensor attached) | 10 | relay | stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass | - | II | Flow monitoring; Wire monitoring | - | - | Connector: 1 x 1/2" | output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed | 90-240 AC | 47-63 | -20-60 | No | - | - | - | pushbutton | No | -15-10 | - | - | - | 20_Millionen | - | - | - | - | - | No | 3 A (250 V AC / 30 V DC); (switching cycles at 3 A load: 100.000; type of switch-off: normally open) | 3.5 | - | - |
Loading...
Number of Channels | 1 |
---|
This page is Control Monitor Sensors, part number SR5906.
You can find the detail information about specifications and dimensions on part number SR5906.
Configure
Basic Attributes
Response Time(s)
Current Consumption(mA)
Type of Short-Circuit Protection
Storage Temperature(°C)
Repeatability of the Set Switch Point(K)
Temperature Range(°C)
Switching Function Wire Break Monitoring
Performance in Case of a Fault
Housing
Max. Voltage Drop Switching Output DC(V)
Switch Point Setting
Selection Liquids / Gases
Application Media
Switching Function Temperature Monitoring
Permanent Current Rating of Switching Output DC(mA)
Short-Circuit Proof
Dimensions(mm)
Protection
Power-On Delay Time(s)
Electrical Design
Materials
Protection Class
Application
Connection
Switching Function Flow Monitoring
Operating Voltage(V)
Frequency AC(Hz)
Ambient Temperature(°C)
Reverse Polarity Protection
Adjustment of the Switch Point
Short-Circuit Protection
Operating Voltage Tolerance(%)
Switching Cycles (Mechanical)
Overload Protection
Contact Rating
Max. Power Consumption(VA)
Filter by standard shipping days
Optional Attributes
Part Number |
---|
SN0150 |
SN0151 |
SN0152 |
SN0500 |
SN2301 |
SN2302 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Response Time (s) | Protection | Power-On Delay Time (s) | Electrical Design | Materials | Current Consumption (mA) | Protection Class | Application | Type of Short-Circuit Protection | Storage Temperature (°C) | Connection | Switching Function Flow Monitoring | Operating Voltage (V) | Frequency AC (Hz) | Ambient Temperature (°C) | Reverse Polarity Protection | Repeatability of the Set Switch Point (K) | Temperature Range (°C) | Switching Function Wire Break Monitoring | Adjustment of the Switch Point | Short-Circuit Protection | Operating Voltage Tolerance (%) | Performance in Case of a Fault | Housing | Max. Voltage Drop Switching Output DC (V) | Switching Cycles (Mechanical) | Switch Point Setting | Selection Liquids / Gases | Application Media | Switching Function Temperature Monitoring | Permanent Current Rating of Switching Output DC (mA) | Overload Protection | Contact Rating | Max. Power Consumption (VA) | Short-Circuit Proof | Dimensions (mm) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
375.29 € | 1 | 4 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | - | II | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 90-240 AC | 47-63 | -20-60 | No | 4 | 0-80 | relay de-energised in case of wire break or short circuit | potentiometer | - | -5-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | 4 | No | 100 x 25 x 103.5 | ||
364.51 € | 1 | 4 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | - | II | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 90-240 AC | 47-63 | -20-60 | No | 4 | 0-80 | relay de-energised in case of wire break or short circuit | potentiometer | - | -5-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay de-energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | 4 | No | 100 x 25 x 103.5 | ||
364.51 € | 1 | 4 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | - | II | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 90-240 AC | 47-63 | -20-60 | No | 4 | 40-120 | relay de-energised in case of wire break or short circuit | potentiometer | - | -5-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay de-energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | 4 | No | 100 x 25 x 103.5 | ||
399.69 € | 1 | 12 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | - | II | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 90-240 AC | 47-63 | -20-60 | No | 4 | 0-80 | relay de-energised in case of wire break or short circuit | potentiometer | - | -5-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | 4 | No | 100 x 25 x 103.5 | ||
882.77 € | 1 | 4 Days | - | IP 40 | 30 | relay | Plastics | - | - | Flow monitoring; Wire monitoring | - | -20-85 | - | relay energised when flow is present | < 230 AC | 47-63 | -20-60 | No | - | - | relay de-energised in case of wire break | potentiometer | - | -10-10 | - | Housing for DIN rail mounting | - | - | - | slide switch | - | - | - | No | 4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC) | 5 | No | 78 x 45 x 120 | ||
882.77 € | 1 | 4 Days | - | IP 40 | 30 | relay | Plastics | - | - | Flow monitoring; Wire monitoring | - | -20-85 | - | relay energised when flow is present | < 110 AC | 47-63 | -20-60 | No | - | - | relay de-energised in case of wire break | potentiometer | - | -10-10 | - | Housing for DIN rail mounting | - | - | - | slide switch | - | - | - | No | 4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC) | 5 | No | 78 x 45 x 120 |