Manufacturer part number: SU9001
Brand: IFM ELECTRONIC
Price: 1,382.09 €
Delivery time: 3 Days
Number of Inputs and Outputs: Number of digital outputs: 2; Number of analogue outputs: 1
Analogue Voltage Output: 0-10; (scalable) V
Electrical Design: PNP/NPN
Application: totaliser function; for industrial applications
Storage Temperature: -13-176 °F
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
SU9001
Part Number
|
---|
SU9001 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Number of Inputs and Outputs | Analogue Voltage Output (V) | Electrical Design | Application | Storage Temperature (°F) | Analogue Current Output (mA) | Process Connection | Accuracy (K) | Storage Temperature (°C) | Ambient Temperature (°C) | Number of Analogue Outputs | Output Function | Repeatability | Max. Load (Ω) | Number of Digital Outputs | Min. Load Resistance (Ω) | Output Signal | Max. Voltage Drop Switching Output DC (V) | Inputs | Measuring Range | Permanent Current Rating of Switching Output DC (mA) | Ambient Temperature (°F) | Pulse Output | Accuracy (In the Measuring Range) | Display | Materials (Wetted Parts) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1,382.09 € | 1 | 3 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | PNP/NPN | totaliser function; for industrial applications | -13-176 | 4-20; (scalable) | threaded connection G 1 1/4 flat seal | ± 5.4 (Q > 0.26 gpm) | - | - | 1 | normally open / normally closed; (parameterisable) | 0.05 gpm; 3 gph | 500 | 2 | 2000 | Switching signal; analogue signal; pulse signal; (configurable) | 2 | counter reset | 0-3170 gph 0-52.84 gpm | 250; (per output) | 14-140 | flow rate meter | < ± (3 % MW + 0.2 % MEW) / < ± (8 % MW + 0.5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) | Display unit: 5 x LED, green (gpm, gph, gal, °F, 10³) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | stainless steel (1.4404 / 316L); FKM; PPS; Centellen 200 |
Loading...
Protection | IP 67 | Power-On Delay Time(s) | 10 | Materials | Housing: AlMgSi0.5 anodised; Sealing: FKM; PA 6.6; cover film: PA |
---|---|---|---|---|---|
Current Consumption(mA) | 100 | Protection Class | III | Type of Short-Circuit Protection | pulsed |
Operating Voltage(V) | 19-30 DC; (according to EN 50178 SELV/PELV) | Electrical Connection | Connector: 1 x M12; Moulded body: brass, Optalloy-plated; Contacts: gold-plated | Reverse Polarity Protection | Yes |
Total Number of Outputs | 2 | Short-Circuit Protection | Yes | Special Feature | Gold-plated contacts |
Application Media | water; glycol solutions; coolants; oil | Overload Protection | Yes | Min. Insulation Resistance(MΩ) | 100; (500 V DC) |
Installation | connection to pipe by means of an adapter |
This page is Ultrasonice Flow Meter, part number SU9001.
You can find the detail information about specifications and dimensions on part number SU9001.
Configure
Basic Attributes
Storage Temperature(°C)
Ambient Temperature(°C)
Number of Inputs and Outputs
Analogue Voltage Output(V)
Electrical Design
Application
Storage Temperature(°F)
Analogue Current Output(mA)
Process Connection
Accuracy(K)
Number of Analogue Outputs
Output Function
Repeatability
Max. Load(Ω)
Number of Digital Outputs
Min. Load Resistance(Ω)
Output Signal
Max. Voltage Drop Switching Output DC(V)
Inputs
Measuring Range
Permanent Current Rating of Switching Output DC(mA)
Ambient Temperature(°F)
Pulse Output
Accuracy (In the Measuring Range)
Display
Materials (Wetted Parts)
Filter by standard shipping days
Optional Attributes
Part Number |
---|
SU7001 |
SU7200 |
SU8000 |
SU8001 |
SU8200 |
SU9004 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Number of Inputs and Outputs | Analogue Voltage Output (V) | Electrical Design | Application | Storage Temperature (°F) | Analogue Current Output (mA) | Process Connection | Accuracy (K) | Storage Temperature (°C) | Ambient Temperature (°C) | Number of Analogue Outputs | Output Function | Repeatability | Max. Load (Ω) | Number of Digital Outputs | Min. Load Resistance (Ω) | Output Signal | Max. Voltage Drop Switching Output DC (V) | Inputs | Measuring Range | Permanent Current Rating of Switching Output DC (mA) | Ambient Temperature (°F) | Pulse Output | Accuracy (In the Measuring Range) | Display | Materials (Wetted Parts) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
938.21 € | 1 | 12 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | PNP/NPN | totaliser function; for industrial applications | -13-176 | 4-20; (scalable) | threaded connection G 3/4 flat seal | ± 5.4 (Q > 0.26 gpm) | - | - | 1 | normally open / normally closed; (parameterisable) | 0.025 gpm; 1.5 gph | 500 | 2 | 2000 | Switching signal; analogue signal; pulse signal; (configurable) | 2 | counter reset | 0-793 gph 0-13.22 gpm | 250; (per output) | 14-140 | flow rate meter | < ± (3 % MW + 0.2 % MEW) / < ± (5 % MW + 0.5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) | Display unit: 5 x LED, green (gpm, gph, gal, °F, 10³) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 | ||
757.45 € | 1 | 4 Days | Number of digital outputs: 2 | - | PNP | For industrial applications | - | - | threaded connection G 3/4 flat seal | 0.2 | -25-80 | -10-60 | - | normally open / normally closed; (parameterisable) | 0.1 l/min (0.025 gpm) | - | 2 | - | Switching signal | 2 | - | 0-50 l/min 0-13.2 gpm | 250; (per output) | - | - | < ± (3 % MW + 0.2 % MEW) / < ± (5 % MW + 0.5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) | - | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 | ||
976.60 € | 1 | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | PNP/NPN | totaliser function; for industrial applications | - | 4-20; (scalable) | threaded connection G 1 flat seal | ± 3 (Q > 1 l/min) | -25-80 | -10-60 | 1 | normally open / normally closed; (parameterisable) | 0.2 l/min; 12 l/h; 0.012 m³ /h | 500 | 2 | 2000 | Switching signal; analogue signal; pulse signal; (configurable) | 2 | counter reset | 0-100 l/min 0-6 m³/h | 250; (per output) | - | flow rate meter | < ± (3 % MW + 0.2 % MEW) / < ± (5 % MW + 0.5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) | Display unit: 6 x LED, green (l/min, m³/h, l, m³, 10³, °C) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 | ||
976.60 € | 1 | 12 Days | Number of digital outputs: 2; Number of analogue outputs: 1 | 0-10; (scalable) | PNP/NPN | totaliser function; for industrial applications | -13-176 | 4-20; (scalable) | threaded connection G 1 flat seal | ± 5.4 (Q > 0.26 gpm) | - | - | 1 | normally open / normally closed; (parameterisable) | 0.05 gpm; 3 gph | 500 | 2 | 2000 | Switching signal; analogue signal; pulse signal; (configurable) | 2 | counter reset | 0-1585 gph 0-26.44 gpm | 250; (per output) | 14-140 | flow rate meter | < ± (3 % MW + 0.2 % MEW) / < ± (5 % MW + 0.5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) | Display unit: 5 x LED, green (gpm, gph, gal, °F, 10³) switching status: 2 x LED, yellow measured values: alphanumeric display, 4-digit programming alphanumeric display, 4-digit | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 | ||
795.94 € | 1 | 4 Days | Number of digital outputs: 2 | - | PNP | For industrial applications | - | - | threaded connection G 1 flat seal | 0.2 | -25-80 | -10-60 | - | normally open / normally closed; (parameterisable) | 0.2 l/min (0.05 gpm) | - | 2 | - | Switching signal | 2 | - | 0-100 l/min 0-26.42 gpm | 250; (per output) | - | - | < ± (3 % MW + 0.2 % MEW) / < ± (5 % MW + 0.5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) | - | stainless steel (1.4404 / 316L); FKM; PES; Centellen 200 | ||
1,408.98 € | 1 | 4 Days | Number of analogue outputs: 2 | - | - | For industrial applications | - | 4-20; (scalable) | threaded connection G 1 1/4 flat seal | ± 3 (Q > 20 l/min) | -25-80 | -10-60 | 2 | - | 1 l/min; 60 l/h; 0.05 gpm; 3 gph | 500 | - | - | Analogue signal | - | - | 0-200 l/min 0-52.84 gpm | - | - | - | < ± (3 % MW + 0.2 % MEW) / < ± (8 % MW + 0.5 % MEW); (water; glycol: 35%; oil: viscosity 68 mm²/s at 40 °C) | - | stainless steel (1.4404 / 316L); FKM; PPS; Centellen 200 |