Electronic Level Sensor (LR7300)

Electronic Level Sensor LR7300

Product Details:

Manufacturer part number: LR7300

Brand: IFM ELECTRONIC

Price: 484.34

Delivery time: 4 Days


Technical Data:

Number of Inputs and Outputs: Number of digital outputs: 2

Analogue Voltage Output: - V

Protection: IP 67

Power-On Delay Time: < 3 s

Electrical Design: PNP


Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

LR7300

Part Number
LR7300
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Number of Inputs and Outputs Analogue Voltage Output
(V)
Protection Power-On Delay Time
(s)
Electrical Design MAWP (for Applications According to CRN)
(bar)
Materials Current Consumption
(mA)
Application Electrical Connection - Plug Type of Short-Circuit Protection Analogue Current Output
(mA)
Process Connection Connection Operating Voltage
(V)
Max. Resistance Switching Output
(Ω)
Electrical Connection Ambient Temperature
(°C)
Cannot Be Used For Output Function Total Number of Outputs Detection Range
(mm)
Number of Digital Outputs Min. Load Resistance
(Ω)
Output Signal Short-Circuit Protection Tank Pressure
(bar)
Dielectric Constant of the Medium Recommended Media Special Feature Application Media Probe Length
(mm)
Permanent Current Rating of Switching Output DC
(mA)
Max. Power-On Delay Time
(ms)
Surface Characteristics Ra/Rz of the Wetted Parts Overload Protection Measuring Range
(mm)
IO-Link Revision Installation Dimensions
(mm)
Materials (Wetted Parts) Transmission Type Maximum Speed of the Change of Level
(mm/s)

484.34 €

1 4 Days Number of digital outputs: 2-IP 67< 3PNP16stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PBT; PC; PEI; TPE-V< 30--thermal, pulsed-3/4"NPT-18-30 DC-Connector: 1 x M12; Contacts: gold-plated-25-60See the operating instructions, chapter "Function and features".normally open / normally closed; (parameterisable)2---Switching signal; IO-LinkYes-1-16≥ 5water; hydrous mediaGold-plated contactsLiquids100-1600---Yes-1.1--stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKMCOM2 (38.4 kBaud)-

Loading...

  1. 1

Basic information

Protection Class III Reverse Polarity Protection Yes Communication Interface IO-Link

This page is Electronic Level Sensor, part number LR7300.
You can find the detail information about specifications and dimensions on part number LR7300.

Variation of this product

Part Number
LK1023
LK1024
LK1222
LR7320
LR8000
LR8010
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Number of Inputs and Outputs Analogue Voltage Output
(V)
Protection Power-On Delay Time
(s)
Electrical Design MAWP (for Applications According to CRN)
(bar)
Materials Current Consumption
(mA)
Application Electrical Connection - Plug Type of Short-Circuit Protection Analogue Current Output
(mA)
Process Connection Connection Operating Voltage
(V)
Max. Resistance Switching Output
(Ω)
Electrical Connection Ambient Temperature
(°C)
Cannot Be Used For Output Function Total Number of Outputs Detection Range
(mm)
Number of Digital Outputs Min. Load Resistance
(Ω)
Output Signal Short-Circuit Protection Tank Pressure
(bar)
Dielectric Constant of the Medium Recommended Media Special Feature Application Media Probe Length
(mm)
Permanent Current Rating of Switching Output DC
(mA)
Max. Power-On Delay Time
(ms)
Surface Characteristics Ra/Rz of the Wetted Parts Overload Protection Measuring Range
(mm)
IO-Link Revision Installation Dimensions
(mm)
Materials (Wetted Parts) Transmission Type Maximum Speed of the Change of Level
(mm/s)

546.78 €

1 4 Days Number of digital outputs: 2-IP 67< 3PNP/NPN-stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV< 50--thermal, pulsed---18-30 DC-Connector: 1 x M120-60extremely conductive media; adhering media; granulates; bulk material; acids; alkali; hygienic areas and electroplating applicationsnormally open / normally closed; (parameterisable)2---Switching signal; IO-LinkYes0.5; (when mounting with mounting accessories: E43001 - E43007. E43019)> 2--hydrous coolants; oils; oil-based media; water; media similar to water472---Yes-1.1-Ø 16PPCOM2 (38.4 kBaud)200

592.34 €

1 4 Days Number of digital outputs: 2-IP 67< 3PNP/NPN-stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV< 50--thermal, pulsed---18-30 DC-Connector: 1 x M12; Contacts: gold-plated0-60extremely conductive media; adhering media; granulates; bulk material; acids; alkali; food and electroplating industrynormally open / normally closed; (parameterisable)2---Switching signal; IO-LinkYes0.5; (when mounting with mounting accessories: E43001 - E43007. E43019)> 2-Gold-plated contactshydrous coolants; oils; oil-based media; water; media similar to water728---Yes-1.1-Ø 16PPCOM2 (38.4 kBaud)300

595.80 €

1 4 Days Number of digital outputs: 2-IP 67< 3PNP/NPN-stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV< 50--pulsed---12-30 DC-Connector: 1 x M12; Contacts: gold-plated0-60extremely conductive media; adhering media; granulates; bulk material; acids; alkali; hygienic areas and electroplating applications-2---Switching signal; IO-LinkYes0.5; (unpressurized for applications to WHG (German Federal Water Act))> 2-Gold-plated contactshydrous coolants; oils; oil-based media; water; media similar to water264---Yes-1.1-Ø 16PPCOM2 (38.4 kBaud)100

412.62 €

1 4 Days Number of digital outputs: 2-IP 68; IP 69K; (7 days / 1 m water depth / 0.1 bar: IP 68)< 3PNP/NPN-stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PEI< 25--pulsed-3/4"NPT-18-30 DC-Connector: 1 x M12; Contacts: gold-plated-25-60-normally open / normally closed; (parameterisable)2---Switching signal; IO-LinkYes-1-16> 5water; hydrous mediaGold-plated contactsLiquids100-2000---Yes-1.1--stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKMCOM2 (38.4 kBaud)-

561.88 €

1 4 Days Number of digital outputs: 4-IP 67< 3PNP16stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; PBT; PC; PEI; TPE-V< 30--thermal, pulsed-G 3/4 external thread-18-30 DC-Connector: 1 x M12; Contacts: gold-plated-25-60See the operating instructions, chapter "Function and features".normally open / normally closed; (parameterisable)4---Switching signal; IO-LinkYes-1-16≥ 1.8; (for media with a dielectric constant of 1.8-5 (e.g. oils), a coaxial pipe is needed for operation)water; hydrous media; oils; oil-based mediaGold-plated contactsLiquids100-1600---Yes-1.1--stainless steel (1.4305 / 303); probe connection: stainless steel (1.4435 / 316L); PTFE; FKM; Sealing: NBR reinforced fibreCOM2 (38.4 kBaud)-

661.15 €

1 4 Days Number of digital outputs: 4-IP 67< 3PNP-stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); FKM; PBT; PC; PEI; TPE-V< 30--thermal, pulsed-G 3/4 external thread-18-30 DC-Connector: 1 x M12; Contacts: gold-plated0-60See the operating instructions, chapter "Function and features".normally open / normally closed; (parameterisable)4---Switching signalYes-0.5-4≥ 2-Gold-plated contactshydrous coolants; oils; oil-based media; water; media similar to water100-1600---Yes-1.1Operation only in conjunction with rod and coaxial pipe.--COM2 (38.4 kBaud)-

Tech Support