Manufacturer part number: JN2100
Brand: IFM ELECTRONIC
Price: 585.38 €
Delivery time: 4 Days
Number of Inputs and Outputs: -
Analogue Voltage Output: - V
Protection: IP 65; IP 67; IP 68; IP 69K
Measuring Range Vehicle Yaw Rate: - °/s
Power-On Delay Time: 300; (warm-up time) s
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
JN2100
Part Number
|
---|
JN2100 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Number of Inputs and Outputs | Analogue Voltage Output (V) | Protection | Measuring Range Vehicle Yaw Rate (°/s) | Power-On Delay Time (s) | Electrical Design | Temperature Coefficient (1/K) | Repeatability (°) | Angular Range (°) | Limit Frequency (Hz) | Materials | Current Consumption (mA) | Max. Current Consumption (mA) | Storage Humidity (%) | Protocol | Protection Class | Application | Frequency Range (Hz) | Accuracy (°) | Analogue Current Output (mA) | Electrical Connection - CAN-OUT | Storage Temperature (°C) | Operating Voltage (V) | Number of Measurement Axes | Electrical Connection | Ambient Temperature (°C) | Reverse Polarity Protection | Number of Analogue Outputs | Max. Initialisation Time (ms) | Process Data Binary | Output Function | Total Number of Outputs | Max. Load (Ω) | Precision Analogue Output (%) | Measuring Range ACceleration (g) | Number of Digital Outputs | Terminating Resistor | Min. Load Resistance (Ω) | Operating Principle | Short-Circuit Protection | Measuring Range of Vibration (mm/s) | Number of CAN Interfaces | Max. Voltage Drop Switching Output DC (V) | Hysteresis (°) | Communication Interface | Resolution (°) | Tightening Torque (Nm) | Measuring Range of Vibration (g) | Permanent Current Rating of Switching Output DC (mA) | Overload Protection | Measuring Principle | Process Data Analogue | Sio mode | Min. Process Cycle Time (ms) | Profiles | Min. Insulation Resistance (MΩ) | IO-Link Revision | Electrical Connection - CAN-IN | Dimensions (mm) | Required Master Port Type | Display | Transmission Type | Accessories (Included) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
585.38 € | 1 | Available | 4 Days | - | - | IP 65; IP 67; IP 68; IP 69K | - | 300; (warm-up time) | - | ≤ ± 0.02 ° | ≤ ± 0.1 | 0-360 / ± 180 | 0.5-10; (parameterisable) | Housing: diecast zinc nickel-plated | 70; (24 V DC. 25 °C) | 310; (9.2 V DC; -40 °C) | - | CANopen CiA DS 301 | III | High-precision inclination measurement in 2 axes for mobile applications | 0.1-400 | ≤ ± 0.5; (absolute) | - | Connector: 1 x M12 | -40-85 | 9.2-30 DC | 2 | - | -40-85 | Yes | - | 1000 | - | - | - | - | - | - | - | Yes; (internal ; parameterisable) | - | - | - | 3200 | 1 | - | ≤ ± 0.05 | CAN | 0.1; (parameterisable) | - | 16; (± 2; ± 4; ±8 g parameterisable) | - | - | MEMS capacitive | - | - | - | - | 100; (500 V DC) | - | - | 90 x 62 x 33.2 | - | Preoperational mode: 1 x LED, green Operational mode: 1 x LED, green flashing fault: 1 x LED, red | - | Protective cover: 1 |
Loading...
This page is Inclination Sensor, part number JN2100.
You can find the detail information about specifications and dimensions on part number JN2100.
Configure
Basic Attributes
Number of Inputs and Outputs
Analogue Voltage Output(V)
Measuring Range Vehicle Yaw Rate(°/s)
Electrical Design
Storage Humidity(%)
Analogue Current Output(mA)
Electrical Connection
Number of Analogue Outputs
Process Data Binary
Output Function
Total Number of Outputs
Max. Load(Ω)
Precision Analogue Output(%)
Measuring Range ACceleration(g)
Number of Digital Outputs
Min. Load Resistance(Ω)
Operating Principle
Short-Circuit Protection
Max. Voltage Drop Switching Output DC(V)
Tightening Torque(Nm)
Permanent Current Rating of Switching Output DC(mA)
Overload Protection
Process Data Analogue
Sio mode
Min. Process Cycle Time(ms)
Profiles
IO-Link Revision
Electrical Connection - CAN-IN
Required Master Port Type
Transmission Type
Protection
Power-On Delay Time(s)
Temperature Coefficient(1/K)
Repeatability(°)
Angular Range(°)
Limit Frequency(Hz)
Materials
Current Consumption(mA)
Max. Current Consumption(mA)
Protocol
Protection Class
Application
Frequency Range(Hz)
Accuracy(°)
Electrical Connection - CAN-OUT
Storage Temperature(°C)
Operating Voltage(V)
Number of Measurement Axes
Ambient Temperature(°C)
Reverse Polarity Protection
Max. Initialisation Time(ms)
Terminating Resistor
Measuring Range of Vibration(mm/s)
Number of CAN Interfaces
Hysteresis(°)
Communication Interface
Resolution(°)
Measuring Range of Vibration(g)
Measuring Principle
Min. Insulation Resistance(MΩ)
Dimensions(mm)
Display
Accessories (Included)
Filter by standard shipping days
Optional Attributes
Part Number |
---|
EC2061 |
EC2082 |
JD1111 |
JN2101 |
JN2200 |
JN2201 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Number of Inputs and Outputs | Analogue Voltage Output (V) | Protection | Measuring Range Vehicle Yaw Rate (°/s) | Power-On Delay Time (s) | Electrical Design | Temperature Coefficient (1/K) | Repeatability (°) | Angular Range (°) | Limit Frequency (Hz) | Materials | Current Consumption (mA) | Max. Current Consumption (mA) | Storage Humidity (%) | Protocol | Protection Class | Application | Frequency Range (Hz) | Accuracy (°) | Analogue Current Output (mA) | Electrical Connection - CAN-OUT | Storage Temperature (°C) | Operating Voltage (V) | Number of Measurement Axes | Electrical Connection | Ambient Temperature (°C) | Reverse Polarity Protection | Number of Analogue Outputs | Max. Initialisation Time (ms) | Process Data Binary | Output Function | Total Number of Outputs | Max. Load (Ω) | Precision Analogue Output (%) | Measuring Range ACceleration (g) | Number of Digital Outputs | Terminating Resistor | Min. Load Resistance (Ω) | Operating Principle | Short-Circuit Protection | Measuring Range of Vibration (mm/s) | Number of CAN Interfaces | Max. Voltage Drop Switching Output DC (V) | Hysteresis (°) | Communication Interface | Resolution (°) | Tightening Torque (Nm) | Measuring Range of Vibration (g) | Permanent Current Rating of Switching Output DC (mA) | Overload Protection | Measuring Principle | Process Data Analogue | Sio mode | Min. Process Cycle Time (ms) | Profiles | Min. Insulation Resistance (MΩ) | IO-Link Revision | Electrical Connection - CAN-IN | Dimensions (mm) | Required Master Port Type | Display | Transmission Type | Accessories (Included) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
94.84 € | 1 | 4 Days | Number of digital outputs: 1 | - | - | - | - | - | - | 0.2 | 2.2-5.5 | - | - | - | - | - | - | - | - | - | 0.2 | - | - | - | 10-30 DC | 1 | Cable: 3.1 m, PVC | - | - | - | - | - | normally open | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 75 x 22 x 16 | - | - | - | - | ||
377.85 € | 1 | Available | 4 Days | Number of analogue outputs: 1 | - | - | - | - | - | - | - | ± 90 | - | - | - | - | 90; (non condensing) | - | - | - | - | 0.1 | 4-20 | - | -40-85 | 20-30 DC | 1 | Connector: 1 x M12 | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 1.8 | - | - | - | - | - | - | - | - | - | - | - | 41 x 41 x 52 | - | - | - | - | |
906.16 € | 1 | Available | 4 Days | - | - | IP 67; IP 68; IP 69K | ± 500 | - | - | ≤ ± 0.008° | ± 0.05 | 0-360 | - | Housing: diecast aluminium black; potting compound: polyurethane resin | < 65; (9 - 30 V DC) | - | - | CANopen | III | High-precision inclination measurement in dynamic applications | - | ± 0.5|± 0.3 | - | - | -40-85 | 9-30 DC | 1; (Z) | - | -40-85 | Yes | - | - | - | - | - | - | - | ± 4 | - | - | - | - | - | - | 1 | - | ≤ ± 0.05 | CAN | 0.01; (parameterisable) | - | - | - | - | MEMS capacitive; (Acceleration sensor ; gyroscope) | - | - | - | - | 100; (500 V DC) | - | Connector: 1 x M12 | 27 x 59 x 105.3 | - | Preoperational mode: 1 x LED, green Operational mode: 1 x LED, green flashing fault: 1 x LED, red | - | Protective cover: 1 | |
676.92 € | 1 | Available | 4 Days | - | - | IP 65; IP 67; IP 68; IP 69K | - | 300; (warm-up time) | - | ≤ ± 0.0008 ° | ≤ ± 0.01 | -45-45 | 0.5-10; (parameterisable) | Housing: diecast zinc nickel-plated | 70; (24 V DC. 25 °C) | 405; (9.2 V DC; -40 °C) | - | CANopen CiA DS 301 | III | High-precision inclination measurement in 2 axes for mobile applications | - | ≤ ± 0.01; (absolute) | - | Connector: 1 x M12 | -40-85 | 9.2-30 DC | 2 | - | -40-85 | Yes | - | 1000 | - | - | - | - | - | - | - | Yes; (internal ; parameterisable) | - | static | - | - | 1 | - | ≤ ± 0.05 | CAN | 0.01; (parameterisable) | - | - | - | - | MEMS capacitive | - | - | - | - | 100; (500 V DC) | - | - | 90 x 62 x 33.2 | - | Preoperational mode: 1 x LED, green Operational mode: 1 x LED, green flashing fault: 1 x LED, red | - | Protective cover: 1 | |
498.46 € | 1 | Available | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 2 | 2-10; (in case of a fault: 1 V) | IP 65; IP 67; IP 68; IP 69K | - | 300; (warm-up time) | PNP/NPN | ≤ ± 0.02 ° | ≤ ± 0.1 | ± 180 | 0.5-10; (parameterisable) | Housing: diecast zinc nickel-plated | 90; (24 V DC. 25 °C) | 330; (9.2 V DC; -40 °C) | - | - | III | High-precision inclination measurement in 2 axes for mobile and industrial applications | 0.1-400 | ≤ ± 0.5; (absolute) | 4-20; (in case of a fault: 2 mA) | - | -40-85 | 9.2-30 DC; (voltage output: 12-30 DC; IO-Link: 18-30 DC) | 2 | - | -40-85 | Yes | 2 | 1000 | 2 | normally open / normally closed; (programmable) | 4 | 220; (220 (9.2-15 V) / 500 (15-30 V)) | ≤ 1 | - | 2 | - | 1000; (10000 (12-13.5 V) / 1000 (13.5-30 V)) | - | Yes | 3200 | - | 2.5 | ≤ ± 0.05 | IO-Link | 0.05 | - | 16; (± 2; ± 4; ±8 g parameterisable) | 125; (125 mA (85° C); 200 mA (60° C); 250 mA (40° C)) | Yes | MEMS capacitive | 2 | Yes | 5 | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | - | 1.1 | - | 90 x 62 x 33.2 | A | operation: 1 x LED, green switch point 1 x LED, yellow | COM2 (38.4 kBaud) | Protective cover | |
553.85 € | 1 | Available | 4 Days | Number of digital outputs: 2; Number of analogue outputs: 2 | 2-10; (in case of a fault: 1 V) | IP 65; IP 67; IP 68; IP 69K | - | 300; (warm-up time) | PNP/NPN | ≤ ± 0.0008 ° | ≤ ± 0.01 | ± 45 | 0.5-10; (parameterisable) | Housing: diecast zinc nickel-plated | 100; (24 V DC. 25 °C) | 380; (9.2 V DC; -40 °C) | - | - | III | High-precision inclination measurement in 2 axes for mobile and industrial applications | - | ≤ ± 0.01; (absolute) | 4-20; (in case of a fault: 2 mA) | - | -40-85 | 9.2-30 DC; (voltage output: 12-30 DC; IO-Link: 18-30 DC) | 2 | - | -40-85 | Yes | 2 | 1000 | 2 | normally open / normally closed; (programmable) | 4 | 220; (220 (9.2-15 V) / 500 (15-30 V)) | ≤ 1 | - | 2 | - | 1000; (10000 (12-13.5 V) / 1000 (13.5-30 V)) | - | Yes | - | - | 2.5 | ≤ ± 0.05 | IO-Link | 0.01 | - | - | 125; (125 mA (85° C); 200 mA (60° C); 250 mA (40° C)) | Yes | MEMS capacitive | 2 | Yes | 5 | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | - | 1.1 | - | 90 x 62 x 33.2 | A | operation: 1 x LED, green switch point 1 x LED, yellow | COM2 (38.4 kBaud) | Protective cover |