Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
Part Number
|
---|
SN0150 |
SN0151 |
SN0152 |
SN0500 |
SN2301 |
SN2302 |
SN2303 |
SN2304 |
SR0127 |
SR0150 |
SR0151 |
SR0153 |
SR2301 |
SR307A |
SR5900 |
SR5906 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Response Time (s) | Protection | Power-On Delay Time (s) | Electrical Design | Materials | Current Consumption (mA) | Protection Class | Application | Type of Short-Circuit Protection | Storage Temperature (°C) | Connection | Switching Function Flow Monitoring | Operating Voltage (V) | Frequency AC (Hz) | Ambient Temperature (°C) | Reverse Polarity Protection | Repeatability of the Set Switch Point (K) | Temperature Range (°C) | Switching Function Wire Break Monitoring | Adjustment of the Switch Point | Short-Circuit Protection | Operating Voltage Tolerance (%) | Performance in Case of a Fault | Housing | Max. Voltage Drop Switching Output DC (V) | Switching Cycles (Mechanical) | Switch Point Setting | Selection Liquids / Gases | Application Media | Switching Function Temperature Monitoring | Permanent Current Rating of Switching Output DC (mA) | Overload Protection | Contact Rating | Max. Power Consumption (VA) | Short-Circuit Proof | Dimensions (mm) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
375.29 € | 1 | 4 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | - | II | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 90-240 AC | 47-63 | -20-60 | No | 4 | 0-80 | relay de-energised in case of wire break or short circuit | potentiometer | - | -5-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | 4 | No | 100 x 25 x 103.5 | ||
364.51 € | 1 | 4 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | - | II | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 90-240 AC | 47-63 | -20-60 | No | 4 | 0-80 | relay de-energised in case of wire break or short circuit | potentiometer | - | -5-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay de-energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | 4 | No | 100 x 25 x 103.5 | ||
364.51 € | 1 | 4 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | - | II | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 90-240 AC | 47-63 | -20-60 | No | 4 | 40-120 | relay de-energised in case of wire break or short circuit | potentiometer | - | -5-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay de-energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | 4 | No | 100 x 25 x 103.5 | ||
399.69 € | 1 | 12 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | - | II | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 90-240 AC | 47-63 | -20-60 | No | 4 | 0-80 | relay de-energised in case of wire break or short circuit | potentiometer | - | -5-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | 4 | No | 100 x 25 x 103.5 | ||
882.77 € | 1 | 4 Days | - | IP 40 | 30 | relay | Plastics | - | - | Flow monitoring; Wire monitoring | - | -20-85 | - | relay energised when flow is present | < 230 AC | 47-63 | -20-60 | No | - | - | relay de-energised in case of wire break | potentiometer | - | -10-10 | - | Housing for DIN rail mounting | - | - | - | slide switch | - | - | - | No | 4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC) | 5 | No | 78 x 45 x 120 | ||
882.77 € | 1 | 4 Days | - | IP 40 | 30 | relay | Plastics | - | - | Flow monitoring; Wire monitoring | - | -20-85 | - | relay energised when flow is present | < 110 AC | 47-63 | -20-60 | No | - | - | relay de-energised in case of wire break | potentiometer | - | -10-10 | - | Housing for DIN rail mounting | - | - | - | slide switch | - | - | - | No | 4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC) | 5 | No | 78 x 45 x 120 | ||
882.77 € | 1 | 4 Days | - | IP 40 | 30 | relay | Plastics | - | - | Flow monitoring; Wire monitoring | - | -20-85 | - | relay energised when flow is present | < 200 AC | 47-63 | -20-60 | No | - | - | relay de-energised in case of wire break | potentiometer | - | -10-10 | - | Housing for DIN rail mounting | - | - | - | slide switch | - | - | - | No | 4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC) | 5 | No | 78 x 45 x 120 | ||
882.77 € | 1 | 12 Days | - | IP 40 | 30 | relay | Plastics | - | - | Flow monitoring; Wire monitoring | - | - | - | relay energised when flow is present | < 240 AC | 47-63 | -20-60 | No | - | - | relay de-energised in case of wire break | potentiometer | - | -10-10 | - | Housing for DIN rail mounting | - | - | - | slide switch | - | - | - | No | 4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC) | 5 | No | 78 x 45 x 120 | ||
251.74 € | 1 | 4 Days | - | IP 50 | < 20 | PNP | Plastics | < 45 | - | Flow monitoring | pulsed | - | terminals: 12 x -2.5 mm² | output switches ON when flow is present | 24 DC | - | 0-60 | Yes | - | - | output switches OFF in case of wire break | potentiometer | Yes | -10-10 | - | Housing for DIN rail mounting | - | - | - | - | Liquids | - | 400 | Yes | - | - | - | 78 x 22.5 x 100 | ||
375.29 € | 1 | 4 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | 90 | III | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 24 DC | - | -20-60 | No | 4 | 0-80 | relay de-energised in case of wire break or short circuit | potentiometer | - | -20-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | - | No | 100 x 25 x 103.5 | ||
391.88 € | 1 | 4 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | 90 | III | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 24 DC | - | -20-60 | No | 4 | 40-120 | relay de-energised in case of wire break or short circuit | potentiometer | - | -20-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | - | No | 100 x 25 x 103.5 | ||
364.51 € | 1 | 4 Days | < 3 | - | 10-80; (adjustable (fixed-value resistors terminals 22-23)) | relay | PBT | 90 | III | Flow monitoring; Temperature monitoring; Wire monitoring | - | - | COMBICON connector | relay energised when flow is present and during the power-on delay time | 24 DC | - | -20-60 | No | 4 | 0-80 | relay de-energised in case of wire break or short circuit | potentiometer | - | -10-10 | In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lights | Housing for DIN rail mounting | - | - | potentiometer | wire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24. | - | relay de-energised when temperature is exceeded | - | No | 4 A (250 V AC / 30 V DC) | - | No | 100 x 25 x 103.5 | ||
882.77 € | 1 | 4 Days | - | IP 40 | 30 | relay | Plastics | 125 | - | Flow monitoring; Wire monitoring | - | - | - | relay energised when flow is present | 24 DC | - | -20-60 | No | - | - | relay de-energised in case of wire break | potentiometer | - | -10-10 | - | Housing for DIN rail mounting | - | - | - | slide switch | - | - | - | No | 4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC) | - | No | 78 x 45 x 120 | ||
882.77 € | 1 | 4 Days | - | IP 20 | 10 | relay | PA | 100 | - | Flow monitoring; Temperature monitoring; Wire monitoring | - | -25-80 | - | relay energised when flow is present | 24 DC | - | -20-60 | No | - | - | - | programming buttons | - | -15-15 | Relay de-energised in case of the following faults: wire break, reverse polarity or short circuit of the sensor cable, undervoltage, internal fault | Housing for DIN rail mounting | - | - | - | - | - | relay de-energised when temperature is exceeded | - | No | 4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC) | - | No | 104.5 x 32.5 x 113.6 | ||
295.92 € | 1 | 4 Days | - | IP 67; (with sensor attached) | 10 | PNP | stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass | < 70 | III | Flow monitoring; Wire monitoring | - | - | Connector: 1 x M12 | output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed | 19-36 DC | - | -20-60 | Yes | - | - | - | pushbutton | Yes | - | - | - | 2.5 | - | - | - | - | - | 250 | Yes | - | - | - | - | ||
323.76 € | 1 | 4 Days | - | IP 67; (with sensor attached) | 10 | relay | stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass | - | II | Flow monitoring; Wire monitoring | - | - | Connector: 1 x 1/2" | output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed | 90-240 AC | 47-63 | -20-60 | No | - | - | - | pushbutton | No | -15-10 | - | - | - | 20_Millionen | - | - | - | - | - | No | 3 A (250 V AC / 30 V DC); (switching cycles at 3 A load: 100.000; type of switch-off: normally open) | 3.5 | - | - |
Loading...
Number of Channels | 1 |
---|
Configure
Basic Attributes
Response Time(s)
Protection
Power-On Delay Time(s)
Electrical Design
Materials
Current Consumption(mA)
Protection Class
Application
Type of Short-Circuit Protection
Storage Temperature(°C)
Connection
Switching Function Flow Monitoring
Operating Voltage(V)
Frequency AC(Hz)
Ambient Temperature(°C)
Reverse Polarity Protection
Repeatability of the Set Switch Point(K)
Temperature Range(°C)
Switching Function Wire Break Monitoring
Adjustment of the Switch Point
Short-Circuit Protection
Operating Voltage Tolerance(%)
Performance in Case of a Fault
Housing
Max. Voltage Drop Switching Output DC(V)
Switching Cycles (Mechanical)
Switch Point Setting
Selection Liquids / Gases
Application Media
Switching Function Temperature Monitoring
Permanent Current Rating of Switching Output DC(mA)
Overload Protection
Contact Rating
Max. Power Consumption(VA)
Short-Circuit Proof
Dimensions(mm)
Filter by standard shipping days
Optional Attributes