Control Monitor Sensors

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
SN0150
SN0151
SN0152
SN0500
SN2301
SN2302
SN2303
SN2304
SR0127
SR0150
SR0151
SR0153
SR2301
SR307A
SR5900
SR5906
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Response Time
(s)
Protection Power-On Delay Time
(s)
Electrical Design Materials Current Consumption
(mA)
Protection Class Application Type of Short-Circuit Protection Storage Temperature
(°C)
Connection Switching Function Flow Monitoring Operating Voltage
(V)
Frequency AC
(Hz)
Ambient Temperature
(°C)
Reverse Polarity Protection Repeatability of the Set Switch Point
(K)
Temperature Range
(°C)
Switching Function Wire Break Monitoring Adjustment of the Switch Point Short-Circuit Protection Operating Voltage Tolerance
(%)
Performance in Case of a Fault Housing Max. Voltage Drop Switching Output DC
(V)
Switching Cycles (Mechanical) Switch Point Setting Selection Liquids / Gases Application Media Switching Function Temperature Monitoring Permanent Current Rating of Switching Output DC
(mA)
Overload Protection Contact Rating Max. Power Consumption
(VA)
Short-Circuit Proof Dimensions
(mm)

375.29 €

1 4 Days < 3-10-80; (adjustable (fixed-value resistors terminals 22-23))relayPBT-IIFlow monitoring; Temperature monitoring; Wire monitoring--COMBICON connectorrelay energised when flow is present and during the power-on delay time90-240 AC47-63-20-60No40-80relay de-energised in case of wire break or short circuitpotentiometer--5-10In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lightsHousing for DIN rail mounting--potentiometerwire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24.-relay energised when temperature is exceeded-No4 A (250 V AC / 30 V DC)4No100 x 25 x 103.5

364.51 €

1 4 Days < 3-10-80; (adjustable (fixed-value resistors terminals 22-23))relayPBT-IIFlow monitoring; Temperature monitoring; Wire monitoring--COMBICON connectorrelay energised when flow is present and during the power-on delay time90-240 AC47-63-20-60No40-80relay de-energised in case of wire break or short circuitpotentiometer--5-10In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lightsHousing for DIN rail mounting--potentiometerwire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24.-relay de-energised when temperature is exceeded-No4 A (250 V AC / 30 V DC)4No100 x 25 x 103.5

364.51 €

1 4 Days < 3-10-80; (adjustable (fixed-value resistors terminals 22-23))relayPBT-IIFlow monitoring; Temperature monitoring; Wire monitoring--COMBICON connectorrelay energised when flow is present and during the power-on delay time90-240 AC47-63-20-60No440-120relay de-energised in case of wire break or short circuitpotentiometer--5-10In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lightsHousing for DIN rail mounting--potentiometerwire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24.-relay de-energised when temperature is exceeded-No4 A (250 V AC / 30 V DC)4No100 x 25 x 103.5

399.69 €

1 12 Days < 3-10-80; (adjustable (fixed-value resistors terminals 22-23))relayPBT-IIFlow monitoring; Temperature monitoring; Wire monitoring--COMBICON connectorrelay energised when flow is present and during the power-on delay time90-240 AC47-63-20-60No40-80relay de-energised in case of wire break or short circuitpotentiometer--5-10In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lightsHousing for DIN rail mounting--potentiometerwire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24.-relay energised when temperature is exceeded-No4 A (250 V AC / 30 V DC)4No100 x 25 x 103.5

882.77 €

1 4 Days -IP 4030relayPlastics--Flow monitoring; Wire monitoring--20-85-relay energised when flow is present< 230 AC47-63-20-60No--relay de-energised in case of wire breakpotentiometer--10-10-Housing for DIN rail mounting---slide switch---No4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC)5No78 x 45 x 120

882.77 €

1 4 Days -IP 4030relayPlastics--Flow monitoring; Wire monitoring--20-85-relay energised when flow is present< 110 AC47-63-20-60No--relay de-energised in case of wire breakpotentiometer--10-10-Housing for DIN rail mounting---slide switch---No4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC)5No78 x 45 x 120

882.77 €

1 4 Days -IP 4030relayPlastics--Flow monitoring; Wire monitoring--20-85-relay energised when flow is present< 200 AC47-63-20-60No--relay de-energised in case of wire breakpotentiometer--10-10-Housing for DIN rail mounting---slide switch---No4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC)5No78 x 45 x 120

882.77 €

1 12 Days -IP 4030relayPlastics--Flow monitoring; Wire monitoring---relay energised when flow is present< 240 AC47-63-20-60No--relay de-energised in case of wire breakpotentiometer--10-10-Housing for DIN rail mounting---slide switch---No4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC)5No78 x 45 x 120

251.74 €

1 4 Days -IP 50< 20PNPPlastics< 45-Flow monitoringpulsed-terminals: 12 x -2.5 mm²output switches ON when flow is present24 DC-0-60Yes--output switches OFF in case of wire breakpotentiometerYes-10-10-Housing for DIN rail mounting----Liquids-400Yes---78 x 22.5 x 100

375.29 €

1 4 Days < 3-10-80; (adjustable (fixed-value resistors terminals 22-23))relayPBT90IIIFlow monitoring; Temperature monitoring; Wire monitoring--COMBICON connectorrelay energised when flow is present and during the power-on delay time24 DC--20-60No40-80relay de-energised in case of wire break or short circuitpotentiometer--20-10In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lightsHousing for DIN rail mounting--potentiometerwire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24.-relay energised when temperature is exceeded-No4 A (250 V AC / 30 V DC)-No100 x 25 x 103.5

391.88 €

1 4 Days < 3-10-80; (adjustable (fixed-value resistors terminals 22-23))relayPBT90IIIFlow monitoring; Temperature monitoring; Wire monitoring--COMBICON connectorrelay energised when flow is present and during the power-on delay time24 DC--20-60No440-120relay de-energised in case of wire break or short circuitpotentiometer--20-10In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lightsHousing for DIN rail mounting--potentiometerwire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24.-relay energised when temperature is exceeded-No4 A (250 V AC / 30 V DC)-No100 x 25 x 103.5

364.51 €

1 4 Days < 3-10-80; (adjustable (fixed-value resistors terminals 22-23))relayPBT90IIIFlow monitoring; Temperature monitoring; Wire monitoring--COMBICON connectorrelay energised when flow is present and during the power-on delay time24 DC--20-60No40-80relay de-energised in case of wire break or short circuitpotentiometer--10-10In case of undervoltage all relays are de-energised; the LED "LOW VOLTAGE/WIRE BREAK-RELAY"lightsHousing for DIN rail mounting--potentiometerwire bridge; on delivery: monitoring of liquids.; for monitoring of gases: link terminals 23 / 24.-relay de-energised when temperature is exceeded-No4 A (250 V AC / 30 V DC)-No100 x 25 x 103.5

882.77 €

1 4 Days -IP 4030relayPlastics125-Flow monitoring; Wire monitoring---relay energised when flow is present24 DC--20-60No--relay de-energised in case of wire breakpotentiometer--10-10-Housing for DIN rail mounting---slide switch---No4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC)-No78 x 45 x 120

882.77 €

1 4 Days -IP 2010relayPA100-Flow monitoring; Temperature monitoring; Wire monitoring--25-80-relay energised when flow is present24 DC--20-60No---programming buttons--15-15Relay de-energised in case of the following faults: wire break, reverse polarity or short circuit of the sensor cable, undervoltage, internal faultHousing for DIN rail mounting-----relay de-energised when temperature is exceeded-No4 A (250 V AC cos phi > 0.7) ; 0.2 A (250 V DC); 4 A (24 V DC)-No104.5 x 32.5 x 113.6

295.92 €

1 4 Days -IP 67; (with sensor attached)10PNPstainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass< 70IIIFlow monitoring; Wire monitoring--Connector: 1 x M12output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed19-36 DC--20-60Yes---pushbuttonYes---2.5-----250Yes----

323.76 €

1 4 Days -IP 67; (with sensor attached)10relaystainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X; brass-IIFlow monitoring; Wire monitoring--Connector: 1 x 1/2"output switches when flow is present: ON for output function = normally open / OFF for output function = normally closed90-240 AC47-63-20-60No---pushbuttonNo-15-10---20_Millionen-----No3 A (250 V AC / 30 V DC); (switching cycles at 3 A load: 100.000; type of switch-off: normally open)3.5--

Loading...